GoMoos Sensor History for Sensor: RMYWM143940
- Manufacturer: RM_Young,
Model: 05106-5
Purchase Date: 2015-09-10
Deployed on Mooring: F0136
- Mooring Details: from 2024-05-05 16:46:00 to 0000-00-00 00:00:00
- Time Event: 2024-05-05 16:46:00, Deployed by R/V Connecticut
- Data_type: wind_gust and Depth: -4 m
Data_type: wind_direction and Depth: -4 m
Data_type: wind_speed and Depth: -4 m
Deployed on Mooring: A0142
- Mooring Details: from 2019-11-26 20:25:00 to 2020-10-05 22:12:00
- Time Event: 2019-11-26 20:25:00, deployed by the R/V Connecticut
Time Event: 2020-10-05 22:12:00, recovered by the R/V Connecticut
Time Event: 2019-12-15 00:01:00, battery voltage has been falling since deployment, daily lows below 11.5 volts now
- Data_type: wind_gust and Depth: -4 m
Data_type: wind_direction and Depth: -4 m
Data_type: wind_speed and Depth: -4 m
Deployed on Mooring: B0131
- Mooring Details: from 2018-03-24 00:25:00 to 2018-10-01 06:50:00
- Time Event: 2018-03-24 00:25:00, Redeployed by R/V Connecticut.
Time Event: 2018-09-08 02:00:00, Last data received from buoy - phone is not registering and backup satellite transmitter is sending same 'no data available for transmission' message (data logger failure?)
Time Event: 2018-10-01 06:50:00, recovered by R/V Connecticut
- Data_type: wind_gust and Depth: -4 m
- Time:2018-07-27 02:10:00, Status: 1
- Comments: Last valid data from backup RMY wind sensor - primary Gill wind sensor working properly.
- Time:2018-07-27 02:10:00, Status: 1
- Comments: Last valid data from backup RMY wind sensor - primary Gill wind sensor working properly.
- Time:2018-07-27 02:10:00, Status: 1
- Comments: Last valid data from backup RMY wind sensor - primary Gill wind sensor working properly.
Deployed on Mooring: B0130
- Mooring Details: from 2018-01-25 18:20:00 to 2018-03-23 21:25:00
- Time Event: 2018-01-25 18:20:00, Redeployed by R/V Connecticut.
Time Event: 2018-03-15 21:00:00, datalogger locked up. Phone on. no data being recorded.
Time Event: 2018-03-16 14:00:00, new datalogger program downloaded to logger (version unknown). Logger is calling in.
Time Event: 0000-00-00 00:00:00, Recovered by R/V Connecticut
Time Event: 2018-03-24 00:00:00, Connectors on top of control box had been incorrectly connedted (swapped battery and solar panel) for B0130 data.
- Data_type: wind_gust and Depth: -4 m
Data_type: wind_direction and Depth: -4 m
Data_type: wind_speed and Depth: -4 m
Deployed on Mooring: E0134
- Mooring Details: from 2016-07-09 14:50:00 to 2016-12-07 15:15:00
- Time Event: 2016-07-09 14:50:00, Redeployed by R/V Connecticut.
Time Event: 2016-11-22 00:00:00, Missing, corrupt or intermittent data from most sensors; problem appears to be with datalogger.
Time Event: 2016-12-07 15:15:00, recovered (box swap) by R/V Ira C.
- Data_type: wind_gust and Depth: -4 m
Data_type: wind_direction and Depth: -4 m
Data_type: wind_speed and Depth: -4 m
Non-Deployment Sensor Events:
- Time Event: 2018-10-01 07:00:00, Event: Damaged
- Comments: Sensor was found to be damaged (dangling below top shelf).
- Time Event: 2018-01-18 00:00:00, Event: Pre-Deployment
- Comments:
- Time Event: 0000-00-00 00:00:00, Event: Post-Recvry: FAIL
- Comments: thermoplastic body smashed